Agfa Cr 75 Installation Manual

CR 75.0 occupies a very small floorspace and at the same time provides unhindered access to several users, both at the input and the output buffer, resulting in a smooth flow of operations. This concept makes CR 75.0 the state-of-the-art solution for centralized CR environments. Universal CR User Station.

' CR 75.0 IS A MULTI-USER DIGITIZER FEATURING A UNIQUE DROP-AND-GO BUFFER THAT ELIMINATES WAITING TIMES AND MAXIMIZES PRODUCTIVITY '

' CR 75.0 IS A MULTI-APPLICATION DIGITIZER, BENEFITING FROM THREE DIFFERENT IMAGE RESOLUTION MODES '

Highest productivity

The cassette buffer eliminates waiting times and allows for a continuous workflow within the department. Zero-button operation with automated cassette handling makes CR 75.0 a highly productive and user-friendly system with a throughput of up to 115 plates an hour, depending on size and application.

No waiting

The CR 75.0 digitizer requires no manual interaction and all the user has to do is to deposit the cassettes in the input buffer (up to 10 cassettes). The digitizer automatically takes cassettes from the input buffer and reads the demographic data from the memory on the cassette. It then scans the imaging plate, digitizes the image and returns the cassette to the output buffer for new exposures.

Full data

CR 75.0 reads imaging plates at a standard resolution of 6 pixels/mm. 10 pixels/mm high resolution capability is available for all image plate sizes. 20 pixels/mm resolution will be available for dedicated 18 x 24 cm and 24 x 30 cm extremities cassettes and plates.

Compact footprint & optimal accessibility

CR 75.0 occupies a very small floorspace and at the same time provides unhindered access to several users, both at the input and the output buffer, resulting in a smooth flow of operations. This concept makes CR 75.0 the state-of-the-art solution for centralized CR environments.

Universal CR User Station

Optionally, a fully integrated CR User Station is available. The CR User Station is suitable for all CR environments:
- Decentralized CR (Surgery, Intensive Care Unit, Emergency Room,...)
- Personal CR
- In-room CR solutions.

Its modular and ergonomic design includes:
- Cassette identification functions
- Space for:

  • Workstation for image handling, processing and dispatching
  • Monitor, network switches and UPS
  • Cassette storage

An economical way to go digital
CR is compatible with all existing X-ray systems allowing X-ray departments to go digital without significant additional investments and workflow adaptations.

Online Enquiry

One moment please...
Not A Member?Sign Up
  • Videos
  • News
DESCRIPTION
Maximizing productivity for the complete range of clinical applications

AGFA CR75 and AGFA CR75-X Highest productivity The cassette buffer eliminates waiting times and allows for a continuous workflow within the department. Zero-button operation with automated cassette handling makes AGFA CR 75.0 a highly productive and user-friendly system with a throughput of up to 115 plates an hour, depending on size and application. AGFA CR 75.0™ DIGITIZER for Computed Radiography Maximizing productivity for the complete range of clinical applications

25.0
FORUMSView All (12)
Ask a New Question

7

Replies
-DrSaj121
4 months ago
4 months agoWrong Cassette Remove and Press + The RIS information could not be retrieved {Ref.MESS75}
Hi i am having the following problems with my CR75.0Wrong Cassette Remove and Press + The RIS information could not be retrieved {Ref.MESS75}The digitizer is not accepting any Cassettes, it keeps giving the error 'Wrong Cassette Remove and Press'At the same time, i'm getting this error message on the software 'The RIS information could not be retrieved {Ref.MESS75}'i have recently tried pairing a different digitizer to the computer, all the IP information seems to be correct. maybe i did something wrong while pairing? we are working in a war zone and have very limited access to experts. please help. Reply
-Oremo
a year ago
a year agoService Manual
Sometimes cassette use to stop along the way while being feed into the machine. A cassette entered today but didn't come out. Later error code Service 22BC7 appeared. I opened the door, brought out the cassette and the imaging plate but the error code still persisted.Reply

1

Reply
-Oremo
2 years ago
2 years agoMachine not booting
I put on my my AGFA CR 75.0 but instead of the booting process (self-testing) to continue, the red light was just blinking and nothing was showing on the display panel. I have powered it off and on again but it is still the samePlease can someone help me with the user manual of the machine or the meaning of this fault.Reply
DOCUMENTS / MANUALSView All


SERVICE COMPANIESView All Computed Radiography Companies

FEATURES

  • No waiting times for improved patient care
  • Input/output buffer for maximized productivity
  • For a broad range of applications

Agfa Cr 75 Installation Manual Pdf

SPECIFICATIONS

Agfa Cr 30 X Manual

CR-System ConfigurationMulti-plate floor unit
Height56 in
Length 45
Weight750.5 lbs
Width33 in